Cost Params
Parameter bundle for a DefaultMultiEchelonCostFormulation. All rate values are denominated in 1 / (modeler-chosen time unit) — the framework performs no time-unit conversion and makes no presumption about what the modeler's rate basis is. The emitted cost-line Responses are therefore reported in the modeler's chosen time unit (a carryingRate of 0.10/year produces a holding cost in $/year; 0.10/day produces it in $/day).
Discrete-event $/event values are dimensionless with respect to time and emit a per-replication total.
Parameters
continuous-rate inventory carrying rate per unit per (modeler-chosen time unit). Multiplies the time-weighted on-hand and on-order averages.
continuous-rate backlog carrying rate per unit per (modeler-chosen time unit). Multiplies the time-weighted backlog average. Default 0.0 disables the continuous backorder-cost line.
$ per replenishment-order event.
$ per inbound shipment.
$ per outbound shipment.
$ per outbound shipment.
$ per stockout event.
$ per lost-sale event.
$ per unit short.
$ per outbound shipment from the external supplier.